Flowline Scrubber Assembly for Control Systems
Designed to provide a regulated instrument gas supply from a high GOR well, the high-low pressure flowline scrubber assembly combines high and low pressure scrubbers connected by a pressure regulator. An automatic drain is provided for discharging any liquid buildup.
| Maximum inlet pressure |
6,000 PSI (414 BAR)
|
| Outlet pressure (field adjustable) |
150 PSI (10 BAR)
|
| Operating temperature |
-20° to 180°F (-29° to 82°C) |
| Outlet flow (maximum) |
38-SCFM at 150-PSI (10.3 BAR)
|
| Minimum GOR |
600 SCF/BBL |
| Relief (safety valve, adjustable) |
250 PSIR (17.2 BAR) |
| Inlet connection |
1-1/2" FNPT |
| Outlet connection |
1" FNPT |
|
 |