SEARCH     
 

2000 Rod Pump Controller Approvals

  • FCC Part 15, Subpart B, Class A Digital Device
  • EU EMC Directive 89/336/EEC
  • CSA approved Industrial Control Equipment–Motor Controller–Miscellaneous

Expansion I/O Boards for the 2000 Rod Pump Controller

Board
Number
Analog
Inputs
Digital
Inputs
Digital
Outputs
Analog
Outputs
1 2 2 2 0
2 4 4 4 0
3 8 4 4* 0
* Can be configured as DI or DO

2000 Rod Pump Controller Specifications

Rod Pump Controller
Enclosure NEMA 4X
Weight Approximately 22 pounds
Input voltage range 480-Vac,120/240-Vac, 12-Vdc
Frequency 47- to 63-Hz
Relay output Control and watchdog
Operating temperature -40° to +185°F (-40° to +85°C)
Printed circuit boards Conformally coated to protect against moisture, H2S, and salt air
Communication protocol Operator selectable, 8500 native, Modbus™ RTU, or Modbus ASCII

Transient Protection
Overvoltage/transient Meets ANSI/IEEE C37.90.1-2989 protection specifications
Dynamometer card resolution Samples and stores load and position data at 20 times-per-second for down-hole analysis
Pump-off or reverse pump-off Detection Setpoint or quadrant method
Analog-to-digital conversion Monolithic, successive approximation 12-bit A/D converter

Polished Rod Load Cell
Class Quantitative strain gauge
Range 0- to 30,000-lb. or 0- to 50,000-lb.
Maximum error ±0.5%
Operating temperature -70° to +190°F (-55° to +88°C)
© 2010 Weatherford International Ltd.