SEARCH     
 
Optimization Systems

Optical Distributed-Temperature-Sensing System Specifications

Operational Performance
  WFT-E10 WFT-6R
Specification range (mi/km) 6.2
10
3.7
6
Maximum operating range (mi/km) 9.3
15
6.2
10
Sampling resolution (ft/m) 3.3
1
1.6 to 3.3
0.5 to 1.0
Spatial resolution (ft/m) < 6.6
< 2
Temperature resolution, temporal (°F/°C) < 0.18°
< 0.1°
Temperature resolution, spatial (°F/°C) < 0.18°
< 0.1°
Measurement interval time 10 sec to 24 hr
Total integration time 3 min to no limit
Short-term stability (°F/°C) < 0.36° over 30 hr
< 0.2° over 30 hr
< 0.18° over 45 hr
< 0.1° over 45 hr
Accuracy (°F/°C) < 5.4° over full operating conditions
< 3° over full operating conditions
Electrical Power
Voltage 100 to 120,
200 to 240 V
24 V DC, 100 to 120,
200 to 240 V AC
Frequency 50 or 60 Hz
Power 60 VA max
Physical Data
Size (DTS module only) 6U 3U
Weight (DTS module only) (lb/kg) 37
17
18
2.2
Plotter weight (lb/kg) 21
9.5
Plotter size (in./mm) 12.3W × 4.87H × 12.0D
312W × 124H × 305D
Environmental Data
Operating temperature (°F/°C) 32° to 104°
0° to 40°
Storage temperature (°F/°C) 14° to 140°
–10° to 60°
Relative humidity 85% max, non-condensing
Operational vibration 5 to 500 Hz, 0.1 g , 90 min/axis
Transportation vibration 5 to 50 Hz, 0.5 g
50 to 500 Hz, 3.0 g
Operation shock 30 g, 11 ms 30 g, 30 ms
Drop test, unpackaged 3-in. height on each plane
75-mm height on each plane

 

Overview
Specifications

© 2011 Weatherford International Ltd.