SEARCH     
 
Optimization Systems

RMS Lite Optical-Sensor Reservoir Monitoring System Specifications

General Specifications
Number of P/T gauges monitoring capability* 3
Number of flowmeters supported 8/Rheos™ module
Number of DTS channels supported 9 or 18/DTS switch
Update rate selectable range 1 sec to no limit
Storage capacity >300 days
Storage capacity with NAS option Typically 5 yr
Units of measure (selectable) Metric, Imperial, oilfield

Output Options
MODBUS, serial 232, 422, 485, and TCP/IP ASCII, RTU, master or slave
Simple serial 232, 422, 485 ASCII
OPC 2.0 data access standard Client and server
Data files by LAN or WAN Flat-file LAS format for DTS
Web-enabled data visualization and transfer Optional
Direct SQL database access ODBC driver

Electrical Power
24 V DC Optional
Voltage range 90 to 264 V AC
Frequency range 47 to 63 Hz
Maximum current 110 0.5 amp
Maximum current 220 1.0 amp
CE low-voltage directive, 73/23/EEC compliant IEC 60204-1

Physical Data
Dimensions (in./mm) 19W x 7H x 21.5D
483W x 178H x 545 D
Weight (lb/kg) 47
21.5

Environmental Data
Operating temperature range (°F/°C) 32° to +104°
0° to +40°
Shipping and storage temperature range (°F/°C) 14° to +122°
–10° to +50°
Thermal shock <18°F/hr
<10°C/hr
Relative humidity, non-condensing, operating range 10 to 80%
Relative humidity, non-condensing, shipping and storage range 0 to 95%
CE electromagnetic compatibility 89/336/EEC compliant EN 61000-3-2, 3-3 EN 61326-1
Operational vibration 3.0 grms, random and sine
Drop (in./mm) 5.9
150

*20,000-PSI (1,379-bar) P/T gauge

 

Overview
Specifications
Diagram

© 2011 Weatherford International Ltd.